0
Authorized Canadian Distributor & Service Centre
Your Cart
(empty)
Cart : (empty)

PEL-5015C-600-1050 - 600V, 1050A, 15kW High Power DC Electronic Load

600V, 1050A, 15kW High Power DC  Electronic Load

GW Instek

Category : High Power Compact DC Load

by quote only Add to Cart

Documents:
Datasheet

Overview
Features
Information
Calibration

GW Instek PEL-5000C series single-channel electronic load provides 150V/ 600V/ 1200V models with a power range of 6kW~24kW. PEL-5000C has a total of 24 models featuring different combinations of power, voltage, and current. It can test and verify the specifications of batteries, electric vehicle chargers/charging stations, electric vehicle batteries and solar panels. PEL-5000C supports parallel connection for same voltage specification and different power models. PEL-5000C can support up to 8 units connected in parallel to provide a maximum power of 192kW.

DC Electronic Load
For the scenario of battery testing, PEL-5000C specifically provides four battery discharge modes, namely CC+CV battery discharge test mode, CP+CV battery discharge test mode, CC+ UVP battery discharge test mode, and CP+ UVP battery discharge test mode. Users can choose a suitable test mode according to the test requirements. In addition to the four battery discharge modes, PEL-5000C also provides Time period discharge, Pulse discharge, and RAMP discharge modes. Users can set the discharge time, or discharge in the pulse current mode, or even set the rising/falling slew rate of the discharge current. These functions can be very flexible in the simulation of the battery discharge current waveform when an electric vehicle is running.

In order to meet the verification requirements of different DUTs, PEL-5000C provides a variety of test functions, including inrush current test mode, solar panel MPPT test mode, automated OCP, OPP test functions and 150 sets of parameter storage function. The 1200V model of PEL-5000C not only provides full power output at 1000V, but also provides 60% power output at 1200V output, which is higher than the 50% power output of other manufacturers of similar electronic loads. High-voltage batteries or chargers directly connected to the electronic load may cause damage to the electronic load. PEL-5000C has a built-in slow starter, which not only protects the DC load, but also saves the user's installation cost and setting time for measurement.

  • Maximum power up to 192KW
  • Up to 8 units of master/slave parallel control
  • 5-digit digital voltage, current and power meter
  • Large LCD Display
  • Display voltage value, current value, watt value at the same time
  • Suitable for power factor regulator (PFC) testing (600V, 1200V models)
  • Automatically perform OCP, OPP test
  • The power-on state value can be set
  • Constant current, constant resistance, constant voltage, constant power, constant current + constant voltage, constant power + constant voltage, dynamic and short circuit modes
  • Short circuit time can be set during short circuit test
  • Over current, over power, over temperature protection and over voltage warning
  • Voltage polarity display can be set to positive value ("+") or negative value ("-")
  • Support solar panel MPPT test
  • Optional interface: GPIB, RS232, USB, LAN

 

Power: 15kW / Current: 0 ~ 1050A

Measurement
Current Read Back
Resolution16.8mA
Range (5 Digital)105 ~ 1050A
Power Read Back
Accuracy *4± 0.06% of (Reading + Range)
Range (5 Digital)15000W
Voltage Read Back
Accuracy± 0.025% of (Reading + Range)
Resolution10mV
Range (5 Digital)60 ~ 600V
Dynamic Mode
Current
Resolution16.8mA
Range105 ~ 1050A
Timing
Resolution0.108A/uS
Slew rate0.432A ~ 27A/uS
Accuracy1uS/10uS/100uS/1mS + 50ppm
Resolution0.001 / 0.01 / 0.1 / 1mS
Thigh & Tlow0.010~9.999 / 99.99 / 999.9 / 9999mS
MPPT Mode
P&O interval1000ms~60000ms ; resolution 1000ms
Load modeCV
AlgorithmP&O
Surge Test
Surge step1~5
Surge time10~1000ms
Surge & Normal current0~1050A
Constant Voltage Mode + Constant Current Mode
Accuracy± 1.0% of (Setting + Range)
Resolution16.8mA
Range1050A
Constant Voltage Mode + Constant Power Mode
Accuracy± 1.0% of (Setting + Range)
Resolution240mW
Range15000W
Constant Power Mode
Accuracy± 0.1% of (Setting + Range)
Resolution240mW
Range15000W
Constant Voltage Mode
Accuracy± 0.5% of (Setting + Range)
Resolution10mV
Range600V
Constant Resistance Mode
Accuracy± 0.2% of (Setting + Range)
Resolution9.536uΩ
Range0.571413Ω ~ 0.009536Ω
Constant Current Mode
Accuracy *3± 0.05% of (Setting + Range)
Resolution16.8mA
Range *21050A

Note *3 : If the operating current is below range 0.1%, the accuracy specification is 0.1% F.S.
Note *2 : The range is automatically or forcing to range II only in CC mode

Protections
Over Temp Protection(OTP)90°C±5°C
Over Voltage Protection(OVP)105%
Over Current Protection(OCP)104%
Over Power Protection(OPP)105%
General
Safety & EMCCE
Temperature *50~40°C
Weight116.5KG
HxWxD(Not included wheels)657mm x 444mm x 763mm
Dimension(HxWxD)761mm x 444mm x 763mm
Power Consumption1100VA
Load OFF Voltage0 ~ 100V
Load ON Voltage0.4 ~ 100V
Maximum Short Current1050A
Typical Short Resistance0.0096Ω
Min.Operatting Voltage10V@1050A
Voltage0 ~ 600V

Note *5: Operating temperature range is 0~40°C, All specifications apply for 25°C±5°C, Except as noted

Note *1 : The power rating specifications at ambient temperature = 25 ̊C

 

Power: 15kW / Current: 0 ~ 105A

Measurement
Power Read Back
Accuracy *4± 0.06% of (Reading + Range)
Range (5 Digital)15000W

Note *4 : Power F.S. = Vrange F.S. x Irange F.S.

Current Read Back
Accuracy± 0.05% of (Reading + Range)
Resolution1.68mA
Range (5 Digital)0 ~ 105A
Voltage Read Back
Accuracy± 0.025% of (Reading + Range)
Resolution1mV
Range (5 Digital)0 ~ 60V
Dynamic Mode
Current
Resolution1.68mA
Range0 ~ 105A
Timing
Resolution0.0108A/uS
Slew rate0.0432A ~ 2.7A/uS
Accuracy1uS/10uS/100uS/1mS + 50ppm
Resolution0.001 / 0.01 / 0.1 / 1mS
Thigh & Tlow0.010~9.999 / 99.99 / 999.9 / 9999mS
MPPT Mode
P&O interval1000ms ~ 60000ms; resolution 1000ms
Load modeCV
AlgorithmP&O
Surge Test
Surge step1~5
Surge time10~1000ms
Surge & Normal current0~1050A
Constant Voltage Mode + Constant Power Mode
Accuracy± 1.0% of (Setting + Range)
Resolution10mV
Range600V
Constant Voltage Mode + Constant Current Mode
Accuracy± 1.0% of (Setting + Range)
Resolution10mV
Range600V
Constant Power Mode
Accuracy± 0.2% of (Setting + Range)
Resolution24mW
Range1500W
Constant Voltage Mode
Accuracy± 0.05% of (Setting + Range)
Resolution10mV
Range600V
Constant Resistance Mode
Accuracy± 0.2% of (Setting + Range)
Resolution29.1674uS
Range34284.8Ω ~ 0.571413Ω
Constant Current Mode
Accuracy *3± 0.05% of (Setting + Range)
Resolution1.68mA
Range *2105A

Note *3 : If the operating current is below range 0.1%, the accuracy specification is 0.1% F.S.
Note *2 : The range is automatically or forcing to range II only in CC mode

Protections
Over Temp Protection(OTP)90℃±5℃
Over Voltage Protection(OVP)105%
Over Current Protection(OCP)104%
Over Power Protection(OPP)105%
General
Safety & EMCCE
Temperature *50~40°C
Weight116.5KG
HxWxD(Not included wheels)657mm x 444mm x 763mm
Dimension(HxWxD)761mm x 444mm x 763mm
Power Consumption1100VA
Load OFF Voltage0 ~ 100V
Load ON Voltage0.4 ~ 100V
Maximum Short Current1050A
Typical Short Resistance0.0096Ω
Min. Operating Voltage10V@1050A
Voltage0 ~ 600V

Note *5: Operating temperature range is 0~40°C, All specifications apply for 25°C±5°C, Except as noted

Note *1 : The power rating specifications at ambient temperature = 25 ̊C

Do you have a 600V, 1050A, 15kW High Power DC Electronic Load that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your 600V, 1050A, 15kW High Power DC Electronic Load calibrated today! Click Here!