PEL-3424H - (800V/ 210A/ 4200W) Single-Channel Programmable D.C. Electronic Load

Overview
Features
Information
Calibration

The PEL-3000 series, a single-channel, programmable D.C. electronic load with 0.01mA current resolution and 16A/μs current Slew Rate, is very ideal for testing server power supply and SPS (Switching Power Supply) for commercial and industrial computers. For a heavy-duty device like cloud ecosystem running 24-hour nonstop operations, a stable and high-power power supply, ranging from 175W to 1050W, is required to maintain the normal operation of server, Hub, and the equipment of data storage and internet communications. Owing to the increasing demand of data transmission and large scale data storage of telecommunications systems, the infrastructure of internet communications is in the pace of rapid expansion. This has greatly boosted the market demand of telecommunications equipment powered by power supply of 2000W and above. The flexible power combination of PEL-3000 meets the test requirements of present high-power power supply.

The PEL-3000H programmable DC Electronic load, which not only inherited functions and features from the PEL-3000 series but providing three current ranges for all PEL-3000H series and adding voltage monitor BNC terminals on the front panel. The PEL-3000H series, a single-channel, programmable D.C. electronic load with 800V and 0.84A/μs current Slew Rate, is ideal for the test of the high voltage devices such as the EV & HEV in-vehicle chargers, DC/DC converters or high-voltage batteries.

  • Operating voltage (DC):0~150V(PEL-3000)/ 0~800V(PEL-3000H)
  • Operating Mode : C.C / C.V / C.R / C.P / CC+CV / CR+CV / CP+CV
  • Parallel Connection of Inputs for Higher Capacity (Max : 9,450W)
  • Support of High Slew Rate:Max. 16A/us((PEL-3000)/ 0.84A/us(PEL-3000H)
  • Run Program Function(GO/NO GO Test)
  • Sequence Function for High Efficient Load Simulations
  • Commands are compatible with Kikusui PLZ-4W model.
  • Dynamic(Switching) Function:0.0166Hz ~20kHz
  • Soft Start Function:Off / On(1~200ms, Res:1ms)
  • Adjustable OCP / OVP / OPP / UVP Setting
  • Short Circuit Function
  • Timer function : Elapsed Time of load on
  • Cut Off Time(Auto Load Off Timer ):1s to 999h 59min 59s or Off
  • External Channel Control / Monitoring via Analog Control Connector
  • Setup Memories:100 sets
  • 3.5 Inch TFT LCD Display
  • Multi Interface : USB 2.0 Device / Host , RS-232 , GPIB (Optional)

CR Mode

Accuracy of setting
H, M±(0.5 % of set*6 + 0.5 % of f.s.*1) + Vin*2/3.24MΩ : Alone operation specifications
L±(0.5 % of set*6 + 0.5 % of f.s.) + Vin*2/3.24MΩ : Alone operation specifications
Operating Range
L42S ~ 0.72mS (23.8095mΩ ~ 1.3889kΩ)
H4.2S ~ 0.72mS (238.095mΩ ~ 13.8889kΩ)
M420mS ~ 0.72mS (2.38095Ω ~ 138.888kΩ)
Resolution
H720µS
M72µS
L7.2µS

CC Mode

Operating Range
H0~157.5A
M0A~15.75A
L0A~1.575A
Accuracy of setting
H, M±(0.2 % of set + 0.1 % of f.s*1) + Vin*2/ 3.24MΩ
L±(0.2 % of set + 0.1 % of f.s) + Vin*2/3.24 MΩ
Resolution
H6mA
M0.6mA
L0.06mA

General

Minimum Operating Voltage
5V210A
2.5V105A
Input Resistance0.81MΩ
Operating voltage(DC)0V~800V
Current0~210A
Power4200W
Input Range90VAC ~ 132VAC/ 180VAC ~ 250VAC Single-phase ; 47Hz~63Hz
Power(Max.)760VA
InterfaceStd: USB, RS-232, Analog Control; Opt: GPIB
Dimensions(mm) & Weight598(W) x 877(H) x 706(D), Approx. 110kg

CV Mode

Operating Range
H5V~800V
L5V~80V
Accuracy of Setting
H, L±(0.1 % of set + 0.1 % of ƒ.s)
Resolution
H20mV
L2mV

CP Mode

Operating Range
H0W~4200W
M0W~420W
L0W~42W
Accuracy of Setting
L±(0.6 % of set + 1.4 % of f.s) + Vin*Vin*3/3.24 MΩ) : Alone operation specifications
H, M±(0.6 % of set + 1.4 % of f.s*3) + Vin*Vin*3/3.24 MΩ : Alone operation specifications
Resolution
H400mW
M40mW
L4mW

Slew Rate

Operation ModeCC, CR
Setting Range (CC mode)
H3.36mA/µs ~ 840mA/µs
M336uA/µs ~ 84mA/µs
L33.6µA/µs ~ 8.4mA/µs
Setting Range (CR mode)
H336µA/µs ~ 84mA/µs
M33.6µA/µs ~ 8.4mA/µs
L3.36µA/µs ~ 840µA/µs
Accuracy of setting±(10% of set + 25µs)
Resolution 1.2mA336mA/µs ~ 840mA/µs
Resolution 120μA33.6mA/µs ~ 84mA/µs
Resolution 12μA3.36mA/µs ~ 8.4mA/µs
Resolution 1.2μA336µA/us ~ 84mA/µs
Resolution 120nA33.6µA/µs ~ 8.4mA/µs
Resolution 12nA3.36µA/µs ~ 0.84mA/µs

Meter

Voltmeter Accuracy±(0.1 % of rdg + 0.1 % of ƒ.s)
Ammeter Accuracy±(1.2 % of rdg + 1.1 % of ƒ.s)

Dynamic Mode

Operation modeCC and CR
T1 & T20.025ms ~ 10ms / Res : 1µs || 10ms ~ 30s/Res:1ms
Accuracy1µS / 1mS ± 100ppm
Slew Rate Setting Range (CC mode)
H3.36mA/µs ~ 840mA/µs
M336µA/µs ~ 84mA/µs
L33.6µA/µs ~ 8.4mA/µs
Slew Rate Setting Rage (CR mode)
H336µA/µs ~ 84mA/µs
M33.6µA/µs ~ 8.4mA/µs
L3.36µA/µs ~ 840µA/µs
Current Accuracy±0.4%F.S.

Protection Functions

FunctionsOvervoltage protection(OVP), Overcurrent protection(OCP), Overpower protection(OPP), Overheat protection(OHP), Undervoltage protection(UVP), Reverse connection protection(REV)