GDS-122 - 20MHz, 2 Channel Handheld Digital Storage Oscilloscope with Multimeter Function

20MHz, 2 Channel Handheld Digital Storage Oscilloscope with Multimeter Function

GW Instek

Category : Oscilloscopes

$799 (USD) Add to Cart

Documents:
Datasheet

Overview
Features
Information
Calibration

This product is discontinued.

Instek GDS-122: GDS-122 is GW Instek’s first handheld oscilloscope launched to the market. It is equipped with 3.8-inch color LCD, which is helpful to clearly show 2 different channel waveforms at one display. Its 100 MSa/s real-time sampling rate and Dual Waveform Math (DWM) function provide users with the fast waveform analyzing capability. What’s more, the additional 6k memory brings the GDS-122 with the impressive accurate data-capturing capability to satisfy diverse industrial requirements. Besides, the DMM mode offers 3 ¾ build-in 4,000 count digital multimeter and auto/manual range adjusting function. No matter in the situation like dealing with voltage, electric current, resistance, diode or even auxiliary measuring, GDS-122 helps obtaining precise information without any delay.

  • 20MHz Bandwidth
  • 100MS/s Real-Time Sampling Rate
  • True RMS Multimeter: Volt, AMp, Ohm, Continuity, Diode
  • Dual Independent Floating Isolated Channels (for Multimeter and Between Oscilloscope and Multimeter).
  • Trigger Mode: Free Run, Single Shot, Edge, Video
  • USB Interface
  • 6 Hour Capacity Li-ion Rechargeable Battery
  • 3.8 Color LCD, Resolution: 320 x 480
  • Light Weight: 690g
SPECIFICATIONS

    
      VERTICAL

 

      Channels
2
      Bandwidth
DC ~ 100MHz (-3dB)
      Rise Time
<3.5ns Approx.
      Sensitivity
2mV/div ~ 5V/div (1-2-5 increments)
      Accuracy
±(3% x |Readout|+0.1 div + 1mV)
      Input Coupling
AC, DC & Ground
      Input Impedance
1M±2%, ~16pF
      Polarity
Normal & Invert
      Maximum Input
300V (DC+AC peak), CATII
      Waveform Signal Process
+ , - , FFT
      Offset Range
2mV/div ~ 50mV/div : ±0.4V
100mV/div ~ 500mV/div : ±4V
1V/div ~ 5V/div : ±40V
      Bandwidth Limit
20MHz (-3dB)

      TRIGGER

 
      Sources
CH1 , CH2 , Line , EXT
      Modes
Auto, Normal, Single, TV, Edge, Pulse Width
      Coupling
AC , DC , LF rej. , HF rej. , Noise rej.
      Sensitivity

DC ~ 25MHz : Approx. 0.5div or 5mV
25MHz ~ 60MHz: Approx. 1.5div or 15mV


      EXT TRIGGER

 
      Range
±15V
      Sensitivity
DC ~ 30MHz : ~ 50mV ; 30M ~ 60MHz : ~100mV
      Input Impedance
1MO±2% , ~ 16pF
      Maximum Input

300V (DC AC peak) , CATII


      HORIZONTAL

 
      Range
1ns/div ~ 10s/div (1-2-5 increments); ROLL : 250ms/div ~ 10s/div
      Modes
Main, Window, Window Zoom, Roll, X-Y
      Accuracy
+0.01%
      Pre-Trigger
10 div maximum
      Post-Trigger
1000 div

      X-Y MODE

      X-Axis Input
Channel 1
      Y-Axis Input
Channel 2
      Phase Shift
±3° at 100kHz

      SIGNAL ACQUISITION

 
      Real-Time Sample Rate
250MSa/s maximum
      Equivalent Sample Rate
25GSa/s maximum
      Vertical Resolution
8 Bits
      Record Length 4K Dots maximum
      Acquisition Mode Normal, Peak Detect, Average
      Peak Detection 10ns (500ns/div ~ 10s/div)
      Average 2 , 4 , 8 , 16 , 32 , 64 , 128 , 256

      CURSORS & MEASUREMENT

 
      Voltage Measurement
Vpp , Vamp , V avg , Vrms , Vhi , V l o , Vmax , Vmin , Rise Preshoot/ Overshoot , Fall Preshoot/Overshoot
      Time Measurement Freq , Period , Rise Time , Fall Time , Positive Width , NegativeWidth , Duty Cycle
      Cursors Measurement

Voltage difference between cursors (ΔV)) Time difference between cursors (ΔT)

      Auto Counter

Resolution : 6 digits
Accuracy : ±2% 
Signal Source: All available trigger source except the Video trigger mode


      CONTROL PANEL FUNCTION

 
      Autoset
Automatically adjusts Vertical VOLTS/DIV, Horizontal TIME/DIV, and Trigger level
 
      Save Setup

Up to 15 sets of measurement conditions

      Save Waveform

15 sets of waveform


      DISPLAY

 
      TFT LCD Type
5.6 inch
      Display Resolution
234 (Vertically) x 320 (Horizontally) Dots
      Display Graticule
8 x 10 divisions
      Display Brightness
Adjustable

      INTERFACE

 
      USB Slave Connector
USB1.1 & 2.0 full speed compatible (printers and flash disk not supported)
      SD Card Slot
Image (BMP), waveform data (CSV), and setup (SET)

      POWER SOURCE  
      Line Voltage Range
AC 100V ~ 240V , 48Hz ~ 63Hz , Auto selection

    MISCELLANEOUS    
     Multi-Language Menu Available
     Online Help Available

      ACCESSORIES

User manual x 1
Power Cord x 1
GTP-060A-2 Probe(10:1/1:1) x 2

      DIMENSIONS & WEIGHT

310(W) x 142(H) x 140(D)mm
Approx. 2.5kg

      OPTION
MODEL
NAME
DESCRIPTION
GTP-100A
Probe
10:1 DC~100MHz, 1:1 DC~6MHz For GDS-810C/810S/1102/2102/2104, GOS-6103/6103C/6112
GTL-110
BNC Cable
BNC Female - BNC Female For GDS Series, GFC-8131H/8270H, GOS Series, GRG-450B, GRS-6052A/6032A, GSG-120/122, SFG-830
GTL-242
USB Cable
For: GDB-02, GDS-800 Series, GDS-1000 Series, GDS-2000 Series, GPD-3303S
GDB-02
Oscilloscope Education and Training Kit
For GDS-800 Series, GDS-1000 Series, GDS-2000 Series

Do you have a 20MHz, 2 Channel Handheld Digital Storage Oscilloscope with Multimeter Function that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your 20MHz, 2 Channel Handheld Digital Storage Oscilloscope with Multimeter Function calibrated today! Click Here!